Conventional Fire Alarm Panel


Gas Release Conventional Fire Alarm Panel
Get Best Price

Product Details

Supply Voltage 230V AC – 50Hz +/- 10 %
Battery voltage 24V DC
Power output 850mW
Normal Operating voltage 24VDC.
Hooter Output 1A.
EOL Resistor 4.7K,1/4watt.
Solenoid nominal V & I 24VDC 1A.
Loop Resistance 50Ω

Functions : After fire in both the zones following operation takes place in sequence, the timer starts. The delay can be set from 0 to 250 sec with the help of dip switch. The Panels Timer LED On and potential Free Timer Relay operates. After the delay is over, relay of solenoid valve operates, 24 V DC output for Solenoid valve and potential Free Gas Release relay also operates.

Abort : After cross zoning the time delay starts and for some reason we do not want to release gas, then short the terminals of ABORT and timer stops. Abort LED on the Panel will glow. Once we release Abort switch then again Timer starts and after set delay, relay of solenoid valve operates.

Manual Release : The Manual release can be achieved by shorting manual release terminals and with set time delay, relay of solenoid valve operates.

Read More...


Yes! I am interested


Jay Je-190 (ERTL) Conventional Fire Alarm Panel
Get Best Price

Features of Products :

  • The panel ranges from 2 to 64 zones.
  • The panel complies with IS 2189 specification.
  • The panel has separate fire and fault indications.
  • The panel also has separate fire and common fault relay.
  • The panel comprises of a 2Amp powe supply unit.
  • Battery backup is provided along with the AC supply.
  • The panel is equipped with a 24VdC piezoelectric buzzer for fault and fire.


Technical Specification :
INTERNAL POWER SUPPLY UNIT

  • Constant potential battery charger 27.5V DC Adjustable.
  • Output Current limited to 2 A.
  • Low battery voltage monitored at 18 V DC Adjustable.
  • Battery charger monitoring for failure.
  • Mains supply monitoring for failure.
  • Mains supply input voltage range 2...

Read More...


Yes! I am interested


Jay JE-1141 Conventional Fire Alarm Panel
Get Best Price

Product Details

Size 375 (H) mm x 300 (W) mm x 100 (D) mm
Operating Temprature 10- 49 degree C
Material M.s. Powder Coated.
Cabling Four wire to be looped.

Features of Products :

  • The panel ranges from 2 to 64 zones.
  • The panel complies with IS 2189 specification.
  • The panel has separate fire and fault indications.
  • The panel also has separate fire and common fault relay.
  • The panel comprises of a 4Amp powe supply unit.
  • Battery backup is provided along with the AC supply.


Technical Specification :
INTERNAL POWER SUPPLY UNIT

  • Constant potential battery charger 14.5V DC.
  • Output Current limited to 3 A.
  • Mains supply input voltage range 230V AC + or – 10 %, 50 Hz.
  • Total panel quiescent current 50mA nominal.
  • Approx. Standby time 4.5 Ah Batt. 24 hrs.
  • Battery recharge time from discharge 3 Hr. approx.


INTERNAL RELAY CONTACT RATIN...