Water Leak Detection System


Leading Manufacturers, Exporters and Wholesaler of Digital Addressable Panel, Conventional Panel and Water Leak Detection Cable from Mumbai.

Business Type Manufacturer, Supplier, Retailer, Wholesaler
Supply Voltage 230V AC – 50Hz +/- 10 %
LCD Display Backlit
Max. Cable length 150 meters
Relay Type Leak Common Relay output
Audible Sounder for Alarm
External Hooter 24VDC
Fuse 2 Amp
Current consumption standby 0.4Amp
Alarm State 1 Amp
Working temperature 10 to 50 *C
Construction Metal Enclosure Wall mounted
Size ( HXWXD) 240x240x100 mm

Click to view more

Preferred Buyer From

Location Anywhere in India

The water leak system comprises of a Master Water leak detection panel (SY-3618), Distance locator Slave modules (MD-450), sensor cable (Synopsys WD-AS) and alarm sounders. The Water leak detection sensor cable typically used to detect water leaks in critical rooms to monitor leakage and to extend alarm to the BMS.

The MD-450 is locally placed in the Server rooms, and communicates with the Master Synopsys Panel through RS-485. It serves as an interface between the Master and the Sensor Cable. The Master panel SY-3618 is to be installed in the BMS room. The master panel will communicate with the clients BMS integration PC-side software using Modbus. The panel will activate a common sounder once the leak/fault is detected. The Master is equipped with a touch screen display and will display the name of the slave and the distance where the leak is been detected in meters.

Salient Features :-

  • Operates on 230V 50 HZ AC
  • Has potential free output and LED indication.
  • Displays distance to leak location in meters.
  • Indicates cable break condition.
  • Maximum length of linear leak detection cable is 150meters.
  • Can detect leak anywhere along the entire cable length.
  • Built in audio sounder and common hooter output.
  • Easy to install and operate.
  • Self-restoring.
  • Soft membrane switches.
  • Communicates with the Master using RS485.
Read More...


Yes! I am interested


Business Type Manufacturer, Supplier, Retailer, Wholesaler
Supply Voltage 230V AC – 50Hz +/- 10 %
LCD Display Backlit.
Relay Zone Relay’s and one common Relay.
SPDT single contact NO-NC.
Internal Sounder Buzzer to indicate Leak.
External Sounder Hooter 24VDC.
Current consumption standby 0.4Amp.
Response Time < 3 Sec.
Alarm State 0.8 Amp.
Working Temp. 10 to 50Degree C.
Construction Metal Enclosure Wall mounted.
Weight 3 Kgs Aprrox.
Size ( HXWXD) : 270x360x115 270x360x115 mm
Tender Specification View

Click to view more

Preferred Buyer From

Location Anywhere in India

The water leak system comprises of a Main zone water leak panel, interface modules, sensor cable and alarm sounders. The water leak panel has potential free relay contacts which extends alarms to BMS.

The Water leak detection sensor cable typically used to detect water leaks in critical rooms to monitor leakage and optionally extend alarm in the BMS. The Cable draws excitation signal from a start of the line module. It serves as an interface between the Water leak detection panel and the Sensor Cable. The Start of Line Interface Module is locally placed in the False Flooring, and shall be connected to the WLD Panel through standard Cu- Ar Cable.

The WLD Panel is be capable of supplying power to the interface modules, and serves as the annunciation of alarms through LCD fascia. The panel activates common sounder. Testing procedure involves physical application of a wet cloth to the cable, to test the relay operation. The Panel sounds the Alarms, and optionally notifies the BMS system.

Features of Products :

  • The panel equipped with LCD Display can monitor 20 Zones.
  • Input to water leak cable is an isolated Ac supply which ensures the cable will not be subject to oxidation and erosion over time avoiding the degradations problems associated with DC system.
  • The panel is equipped with SPDT keypad for navigation.
  • Compact and elegant looks.
Read More...


Yes! I am interested


Business Type Manufacturer, Supplier, Retailer, Wholesaler
Material PVC Twisted Pair With Stainless Steel 316 Elements
Leader Cable 3 mtrs
Dimensions 3.5mm dia
No. of Wires 4 – 2 water sensitive and two data sensitive
Max cable length 150 mtrs
Std cable lengths 10,15,20,25,30 and so on upto 150 mtrs.
Guarantee 12 months from the date of supply.

Preferred Buyer From

Location Anywhere in India

Water Leak Detection Conventional System (WD-AS) uses water leak cable in conjunction with Water Leak Panels to detect water under floors.

Features of Products :

  • Water Leak Detection cable consists of four conductors, two water sensitive and two data.
  • The cable is restorable and corrosion resistant and does not require replacement after being wet.
  • Cable can be installed in the path of a potential water leak.


Installation and Testing :

  • Installation: Install the WLD cable on the floor. Connect the leader end of WLD cable to WLD Panel.
  • Testing: Immerse the WLD cable in water to stimulate a water leak. An alarm will be sent to WLD Panel and the display the leak distance in meters. Dry the WLD Cable to restore in normal mode.
Read More...


Yes! I am interested




Raise your Query

Hi! Simply click below and type your query.

Our experts will reply you very soon.

WhatsApp Us